Accurate and consistent measurements.
BM3201 4-GAS ANALYZER
Both an anti-pollution control tool and a diagnostic tool.
Product Description
Product description
The BM3201 4-gas analyzer is for emission testing of vehicles.
The analyzer features a range of options that allows for a customized configuration.
OPTIONS
-
-
Robust and long lasting.
-
Low maintenance costs.
-
Graphic screen and 5-key keyboard.
-
Guided test procedure on LCD display and handheld unit.
-
Thermal integrated printer (or Matrix Dot on demand).
-
Intelligent control of gas pump via handheld unit to ensure long pump lifetime.
-
Compatible with the OIML R99 Class 0 and ISO 3930 standards.
-
Multi-gas analysis mode.
-
Vehicle inspection mode.
-
Automatic condensation extraction.
-
- Allows for fully automated one or multilane test facilities.
-
Can be supplied with mobile trolley for easy movement:
- Standard trolley or “tough”
trolley.

- Standard trolley or “tough”
trolley.
Technical Data
Technical data
| SIZE OF DISPLAY UNIT (LXWXH) | 400 x 380 x 200 mm |
|---|---|
| PREHEATING TIME | < 5 min at 20°C (1 minute minimum) |
| RESPONSE TIME |
13 seconds for HC, CO, CO2 28 seconds for oxygen |
| NOMINAL PUMP DELIVERY | 6 l/min. |
| MINIMUM PUMP DELIVERY | 3.5 l/min. |
| HOSE LENGTH FOR GAS SAMPLING PROBE | 7.5 m |
| AIR PRESSURE VARIATION | Automatic correction by integrated absolute pressure sensor |
| ZERO POINT AND SENSITIVITY | Automatic compensation |
| PUMP STANDBY AND ZEROING | Automatic |
| POWER SUPPLY X 1 |
0.9 A / 230 Vac
(+10-15%) 1.5 A / 115 Vac |
| HC |
Normal resolution: 0 to 20000 ppm Propane 10 ppm accuracy Normal res.: 10 ppm vol. High res.: 1 ppm vol. |
| CO |
-0.03 à 10.5% 0.03% accuracy Normal res.: 0.01% vol. High res. 0.001% vol. |
| CO₂ |
-0.4 à 21.0 % 0.5% accuracy Normal res.: 0.1% vol. |
| O₂ |
-0.5 à 21.7 % 0.1% accuracy If O₂<4% vol. high res.: 0.01% vol. Otherwise normal res.: 0.1% vol. |
| NOX |
0 à 5000 ppm Res.: 1 ppm vol. |
| ENGINE SPEED |
0 à 9999 RPM +/- 10 RPM accuracy Res.: 1 tours/min. |
| OIL TEMPERATURE |
-5 à 150°C +/- 1°C accuracy Res.: 1°C |
| CORRECTED CO |
0 à 10% 0.03% accuracy Res.: 0.01% |
| AIR/FUEL COEFFICIENT (LAMBDA) |
0.600 to 1.200 0.03 accuracy Res.: 0.001 or 0.01 (selectable) |
| SIZE STANDARD TROLLEY (LXWXH) | 500 x 500 x 1000 mm |
| SIZE “TOUGH” TROLLEY (LXWXH) | 550 x 550 x 1300 mm |
Advantages
Advantages
- Latest technology and software meeting authority requirements.
- Handheld units allow the operator to operate from inside the vehicle.
Installation